全自动超声波清洗机跑起来以后,非常容易被当成摆设的一根管子,是溢流槽。新机调试时水清、看着漂亮,很多班组图省水,把溢流阀关小甚至关死,靠“定期整槽换液”顶着用。结果就是:前两槽还行,末道漂洗开始挂灰、工件出槽带水痕,电镀/喷涂前处理良率慢慢往下掉。
After the fully automatic ultrasonic cleaning machine starts running, the most easily used pipe for decoration is the overflow tank. When debugging a new machine, the water is clear and looks beautiful. Many shift plans save water by turning down or even closing the overflow valve, relying on "regular tank replacement" to support the use. The result is that the first two slots are okay, but the last rinse starts to accumulate dust and the workpiece leaves the slot with water marks. The yield rate of electroplating/spraying pre-treatment slowly decreases.
溢流的本质不是“排水”,是把浮油和悬浮颗粒连续带出槽面。超声空化把油污从工件上打下来,油比水轻浮在表面,颗粒悬浮在中层;不溢流,它们就在槽里循环,等下一篮工件进来再附着一遍。这就是为什么“超声功率够、清洗剂也对,洗完还是发雾”。
The essence of overflow is not "drainage", but to continuously carry floating oil and suspended particles out of the groove surface. Ultrasonic cavitation removes oil stains from the workpiece, making the oil lighter than water on the surface and particles suspended in the middle layer; Without overflow, they circulate in the groove and attach again when the next basket of workpieces comes in. That's why the ultrasound power is sufficient and the cleaning agent is also appropriate, but it still produces mist after washing.

实操里三件事比换液更常救场:
In practice, there are three things that save the scene more often than changing the fluid:
粗洗槽开连续溢流,漂洗槽开小溢流。粗洗油多,表面油膜建议一直撇走;末道漂洗用去离子水,小流量溢流保持水质不倒退即可,别为省水关死。
Open continuous overflow in the coarse washing tank and small overflow in the rinsing tank. There is a lot of coarse washing oil, and the surface oil film must be constantly skimmed away; Use deionized water for the final rinse, and ensure that the water quality does not regress with a small flow overflow. Do not shut it down to save water.
溢流口高度定在液面下 20–30 mm。太高撇不到油膜,太低把好液也放跑了。槽沿自带溢流堰的,别拿胶带贴住半边。
The height of the overflow port is set at 20-30 mm below the liquid level. If it is too high, the oil film cannot be skimmed, and if it is too low, the good liquid will also be released. If there is an overflow weir along the groove edge, do not stick tape on half of it.
配油水分离/撇油器再谈省液。光溢流不撇油,油还是在水里打转;加个小型撇油盘或离心分离,清洗液寿命能拉长一截,换液周期从“几天一换”变成“按 pH 和电导率换”。
Let's talk about saving liquid again with oil-water separation/skimmer. Light overflow does not skim the oil, but the oil still spins in the water; By adding a small oil skimmer or centrifugal separation, the lifespan of the cleaning solution can be extended, and the replacement cycle can be changed from "every few days" to "according to pH and conductivity".
还有个反直觉点:新液刚配好要先脱气 5–8 分钟再开超声。水里溶解气没赶走,空化泡被“软气”垫着,冲击力掉一大截,这时候你看到“洗不干净”会误以为功率不够,其实是脱气没做。
There is another counterintuitive point: the new liquid should be degassed for 5-8 minutes before turning on the ultrasound. The dissolved gas in the water has not been driven away, and the cavitation bubbles are cushioned by "soft gas", causing a significant drop in impact force. At this point, if you see "unable to clean thoroughly", you may mistakenly think that the power is not enough, but in fact, it is because the degassing has not been done.
验收时别只拍工件照片,加两条现场记录:溢流流量(L/min)和末槽电导率(μS/cm)。电导率飘了先查溢流有没有堵、滤芯有没有压差报警,再谈换液。
Don't just take photos of the workpiece during acceptance, add two on-site records: overflow flow rate (L/min) and final tank conductivity (μ S/cm). If the conductivity drifts, first check if there is any blockage in the overflow and if there is a pressure difference alarm in the filter element, and then talk about changing the liquid.
全自动线省的是人工,不省“液路管理”。溢流开对了,超声才是在洗工件,不是在洗自己那槽脏水。
The fully automated line saves on manual labor, not on "fluid management". The overflow is on the right side, ultrasound is washing the workpiece, not washing my own dirty water tank.